Removing the herring-bone pattern-noise from *all* STIS Side-2 CCD data: a factor ~3 enhancement in sensitivity

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

When STIS resumed operations in July 2001 using the redundant "Side-2" electronics, the read-noise of the CCD detector appeared to have increased by ~1 e- due to a superimposed and highly variable "herring-bone" pattern-noise. For the majority of programs aiming to detect signals near the STIS design limits, the impact of this noise is far more serious than implied by a mere 1 e- increase in the amplitude of the read-noise, as it is of a systematic nature. We have perfected a method to cleanly remove this pattern-noise from raw STIS CCD frames. It is robust, but too costly in terms of CPU time and overhead to incorporate into the regular HST/STIS OTFR-pipeline. Systematic application therefore demands a one-time dedicated off-line effort beyond the scope of the work outlined in the STIS close-out calibration plan. As a service to the STIS user community, we propose to fully remove this excess noise from *all* raw, un-binned, "Side-2" STIS/CCD frames, and so significantly augment the potential of the STIS data base for future NUV--NIR archival research. The noise characteristics and effective sensitivity of the resulting cleaned data, to be delivered back to the HST Archive, will closely match those of CCD data taken during operations with the primary electronics --- representing a gain of a factor ~3 in sensitivity at faint flux levels, at low surface-brightness levels, as well as at small spatial scales. All software will be documented and made available to the community. This archival calibration legacy program requests a modest, but necessary, investment of resources to assure a long-lasting STIS legacy. Science programs that will benefit include: 1 *all* STIS/CCD spectroscopy of faint point- or extended sources; 2 *all* STIS/CCD imaging of faint point sources or low surface-brightness extended sources; and 3 *all* STIS/CCD programs that combine data obtained with both primary and redundant electronics.;

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Removing the herring-bone pattern-noise from *all* STIS Side-2 CCD data: a factor ~3 enhancement in sensitivity does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Removing the herring-bone pattern-noise from *all* STIS Side-2 CCD data: a factor ~3 enhancement in sensitivity, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Removing the herring-bone pattern-noise from *all* STIS Side-2 CCD data: a factor ~3 enhancement in sensitivity will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-780992

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.