Effects of temporal dimensional instability on the Advanced X-ray Astrophysics Facility (AXAF-I) high-resolution mirror assembly (HRMA)

Physics – Optics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

The NASA Advanced X-ray Astrophysics Facility-Imaging (AXAF-I), one of NASA's Great Observatories, will be launched in 1998. The AXAF-I High Resolution Mirror Assembly (HRMA) will provide sub-arc second imaging resolution over the expected mission life of five years. During assembly and operational life of the telescope, small dimensional changes of the structural support system can degrade the telescopes resolving power by introducing unwanted forces. The forces that are introduced depend, in part, on the long term temporal dimensional stability of the materials that are used in the telescope. A year-long stability study carried out at the university of Arizona Dimensional Stability Laboratory recently concluded. Cyanate ester-based composites, 7050-T7451 aluminum, LR-35 invar, 6Al-4V titanium, 6061-T6 aluminum and Zerodur were studied. The Zerodur material was found to be stable to better than 0.03 ppm/yr. The titanium was found to be stable to better than 0.5 ppm/yr. The 7050- T7451 aluminum and cyanate ester-based composites were found relatively unstable but their instability improved significantly with time. Monte-Carlo and deterministic techniques were used to predict the effects of the instability on the telescopes' performance. Temporal instability effects were within the systems top level requirements.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Effects of temporal dimensional instability on the Advanced X-ray Astrophysics Facility (AXAF-I) high-resolution mirror assembly (HRMA) does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Effects of temporal dimensional instability on the Advanced X-ray Astrophysics Facility (AXAF-I) high-resolution mirror assembly (HRMA), we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Effects of temporal dimensional instability on the Advanced X-ray Astrophysics Facility (AXAF-I) high-resolution mirror assembly (HRMA) will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-761820

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.