Physics – Instrumentation and Detectors
Scientific paper
2002-06-13
Nucl.Instrum.Meth. A508 (2003) 83-87
Physics
Instrumentation and Detectors
Presented at RPC2001-VI Workshop on Resistive Plate Chambers and Related Detectors, Coimbra, Portugal, 26-27 November 2001
Scientific paper
10.1016/S0168-9002(03)01282-8
We have demonstrated that small gap (0.1 to 0.4 mm) RPCs made of low
resistivity materials (less than 1E8 Ohm.cm) can operate at counting rates of
up to 1E5 Hz/mm2 with position resolutions better than 50 micrometer. Results
of preliminary tests allow us to suggest a possible application of this new
type of RPC for tracking.
Fonte P.
Francke Tom
Peskov V.
Rantanen J.
No associations
LandOfFree
Potential of RPCs for tracking does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Potential of RPCs for tracking, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Potential of RPCs for tracking will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-690231