PIN Photodiodes for Radiation Monitoring and Protection in the BaBar Silicon Vertex Tracker

Physics – High Energy Physics – High Energy Physics - Experiment

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

4 pages, 2 PostScript figures

Scientific paper

We discuss the design, implementation and performance of the radiation monitoring and protection system used by the Silicon Vertex Tracker (SVT) in the BaBar detector. Using 12 reverse-biased PIN photodiodes mounted around the beampipe near the IP, we are able to provide instantaneous radiation dose rates, absorbed dose integrals, and active protection that aborts the circulating beams in the PEP-II storage ring when radiation levels exceed user-defined thresholds. The system has reliably protected the SVT from excessive radiation damage and has also served as a key diagnostic tool in understanding radiation backgrounds at PEP-II.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

PIN Photodiodes for Radiation Monitoring and Protection in the BaBar Silicon Vertex Tracker does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with PIN Photodiodes for Radiation Monitoring and Protection in the BaBar Silicon Vertex Tracker, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and PIN Photodiodes for Radiation Monitoring and Protection in the BaBar Silicon Vertex Tracker will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-45988

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.