Shower Leakage Correction in a High Granularity Calorimeter

Physics – Instrumentation and Detectors

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

7 pages, 6 figures, LCWS2011

Scientific paper

In the ILD detector, HCAL is inside the coil. The HCAL is about 5 interaction length thick, and ECAL is about 1 interaction length thick. For example, an eighty GeV hadron, it is only 95% energy will be contained in ECAL plus HCAL. We need a topological reconstruction of the leakage. This has been studied with experimental data collected using the CALICE prototypes, during the 2007 test beam campaign at CERN. The complete setup of the experiment consisted of a silicon-tungsten electromagnetic calorimeter, an analog scintillator-steel hadron calorimeter and a scintillator-steel tail catcher. Events collected using pion beams in the energy range 8-100 GeV are selected and compared to the Monte Carlo simulations. While the leakage from the full setup is negligible, when removing the tail catcher information either partly or completely the energy loss becomes significant and affects the performance. The average measured energy decreases below the expected beam energy and the resolution deteriorates. A correction to the leakage was implemented for pions. The results obtained show that the correction is powerful in restoring the mean value of the measured energy distributions back to the expected beam energy, with an accuracy at the 1-2% level over the whole energy range. The relative improvement on the resolution is about 25% at 80 GeV, decreasing at lower energies together with the impact of the leakage.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Shower Leakage Correction in a High Granularity Calorimeter does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Shower Leakage Correction in a High Granularity Calorimeter, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Shower Leakage Correction in a High Granularity Calorimeter will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-359995

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.