Spectrum standardization for laser-induced breakdown spectroscopy measurements

Physics – Plasma Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

LIBS; Normalization; quantitative measurement; plasma property

Scientific paper

This paper presents a spectra normalization method for laser-induced breakdown spectroscopy (LIBS) measurements by converting the recorded characteristic line intensity at varying conditions to the intensity under a standard condition with standard plasma temperature, degree of ionization, and total number density of the interested species to reduce the measurement uncertainty. The characteristic line intensities of the interested species are first converted to the intensity at a fixed temperature and standard degree of ionization but varying total number density for each laser pulse analysis. Under this state, if the influence of the variation of plasma morphology is neglected, the sum of multiple spectral line intensities for the measured element can be regarded proportional to the total number density of the specific element, and the fluctuation of the total number density, or the variation of ablation mass, was compensated for by the application of this relationship. In the experiments with 29 brass alloy samples, the application of this method to determine Cu concentration shows a significant improvement over generally applied normalization method for measurement precision and accuracy. The average RSD value, average value of the error bar, R2, RMSEP, and average value of the maximum relative error were: 5.29%, 0.68%, 0.98, 2.72%, 16.97%, respectively, while the above parameter values for normalization with the whole spectrum area were: 8.61%, 1.37%, 0.95, 3.28%, 29.19%, respectively.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Spectrum standardization for laser-induced breakdown spectroscopy measurements does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Spectrum standardization for laser-induced breakdown spectroscopy measurements, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Spectrum standardization for laser-induced breakdown spectroscopy measurements will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-223460

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.