Submillimeter nuclear medical imaging with a Compton Camera using triple coincidences of collinear β+ annihilation photons and γ-rays

Physics – Instrumentation and Detectors

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

2 pages, 1 figure, ICTR-PHE 2012 Conference contribution

Scientific paper

Modern PET systems reach a spatial resolution of 3-10 mm. A disadvantage of this technique is the diffusion of the positron before its decay with a typical range of ca. 1 mm (depending on its energy). This motion and Compton scattering of the 511 keV photons within the patient limit the performance of PET. We present a nuclear medical imaging technique, able to reach submillimeter spatial resolution in 3 dimensions with a reduced activity application compared to conventional PET. This 'gamma-PET' technique draws on specific positron sources simultaneously emitting an additional photon with the \beta+ decay. Exploiting the triple coincidence between the positron annihilation and the third photon, it is possible to separate the reconstructed 'true' events from background. In order to test the feasibility of this technique, Monte-Carlo simulations and image reconstruction has been performed. The spatial resolution amounts to 0.2 mm (FWHM) in each direction, surpassing the performance of conventional PET by about an order of magnitude. The simulated detector geometry exhibits a coincidence detection efficiency of 1.92e-7 per decay. Starting with only 0.7 MBq of source activity (ca. 200-500 times less compared to conventional PET) an exposure time of 450 s is sufficient for source reconstruction.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Submillimeter nuclear medical imaging with a Compton Camera using triple coincidences of collinear β+ annihilation photons and γ-rays does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Submillimeter nuclear medical imaging with a Compton Camera using triple coincidences of collinear β+ annihilation photons and γ-rays, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Submillimeter nuclear medical imaging with a Compton Camera using triple coincidences of collinear β+ annihilation photons and γ-rays will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-187281

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.