Model calculations of the response of CZT strip detectors

Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

4

Scientific paper

Position-sensitive CZT detectors for research in astrophysics in the five - several hundred keV range are being developed by several groups. These are very promising for large area detector arrays in coded mask imagers and small-area focal plane detectors for focusing x-ray telescopes. We have developed detectors with crossed-strip readout and optimized strip widths and gaps to improve energy resolution. A 'steering electrode' is employed between the anode strips to improve charge collection. A model of charge drift in the detectors and charge induction on the electrodes has been developed to allow us to better understand these types of detectors and improve their design. The model presently accounts for the electric field within the detector, the charges' trajectories, mobility and trapping of holes and electrons, and charge induction on all electrodes including their time dependence. Additional effects are being added. The model is described and its predictions are compared with laboratory measurements. Results include (1) the dependence of anode, cathode and steering electrode signal on interaction depth, transverse position, electron and hole trapping, strip width and gap, and bias, (2) trajectories of charges for various anode and steering electrode bias voltages, (3) a method to improve energy resolution by sign depth of interaction information, and (4) an electrode geometry and bias optimized for the improved energy resolution. In general, the model provides good agreement with the measurements.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Model calculations of the response of CZT strip detectors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Model calculations of the response of CZT strip detectors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Model calculations of the response of CZT strip detectors will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1545598

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.