The active thermal control system on the Wide Field Camera on Rosat was designed to provide an acceptable operating temperature for the optics as well as having the capability for controlling the temperature gradients of the camera to maximize its optical capability. This paper contains a description of the thermal design and reports on the in-orbit performance of the control system since the launch of Rosat in mid-1990.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

The in-orbit thermal control of the Wide Field Camera on Rosat does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with The in-orbit thermal control of the Wide Field Camera on Rosat, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and The in-orbit thermal control of the Wide Field Camera on Rosat will most certainly appreciate the feedback.