Monitoring of the mesospheric sodium layer using a magneto-optical filter

Physics – Optics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

Adaptive optics (AO) systems for atmospheric turbulence compensation require a bright reference star for measuring and correcting wavefront distortion. For these reasons a general use of AO requires a laser guide star (LGS) to provide the wavefront information. An artificial guide star can be created by focusing a laser beam tuned to the sodium D2 line at 5890 Angstrom on the mesospheric sodium layer at about 90 km altitude and observing the resonant scattering. The D1 line of the sodium layer can be observed in absorption on early type unreddened (or slightly reddened) stars using a high resolution spectroscopic system. Recent studies have reported that the column density of the layer is temporally variable with timescales from a year down to tens of minutes. Therefore a monitoring of the column density is necessary when observing with sodium LGS. It is demonstrated that, with a sufficiently high spectral resolution, a relatively small (50 cm) telescope observing a bright star can collect in minutes the number of photons necessary to measure the equivalent width of the sodium line with a good signal-to-noise ratio, provided that an efficient spectroscopic device of suitable resolution is attached to it. We propose here a system to monitor the column density of the mesospheric sodium layer which is based on the sodium magneto-optical filter developed by A. Cacciani and already widely used in solar observations since the 70s. This filter is compact, stable in wavelength and profile shape, with high efficiency (up to 40%) and narrow profile width (20 mA). It is based on the magneto-optical activity of the sodium gas embedded in a strong transverse magnetic field. The filter has a central bandpass that can be fitted to the width of the D1 mesospheric line, plus two lateral symmetric bandpasses that observe the adjacent stellar continuum. The D1 equivalent width can be derived by observing the mesospheric sodium line in absorption on the spectrum of a bright early type (O, B, A) star.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Monitoring of the mesospheric sodium layer using a magneto-optical filter does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Monitoring of the mesospheric sodium layer using a magneto-optical filter, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Monitoring of the mesospheric sodium layer using a magneto-optical filter will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1481135

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.