Physics
Scientific paper
Jul 1997
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1997spie.3113..181b&link_type=abstract
Proc. SPIE Vol. 3113, p. 181-192, Grazing Incidence and Multilayer X-Ray Optical Systems, Richard B. Hoover; Arthur B. Walker; E
Physics
13
Scientific paper
The AXAF-payload consisting of a high resolution telescope, two different transmission gratings and two imaging detection systems, has been extensively tested between mid December 1996 and the end of April 1997. In this paper we report a few preliminary results on the resolution of the low energy transmission grating spectrometer. The measurements reported here utilize different x-ray sources and different detector systems. The resolving power at long wavelength ((Delta) (lambda) at 130 angstrom) equals 0.074 angstrom.
Braeuninger Heinrich W.
Brinkman Albert C.
Dewey Daniel
Drake Jeremy J.
Flanagan Kathryn A.
No associations
LandOfFree
Preliminary test results on spectral resolution of the Low Energy Transmission Grating Spectrometer on board of AXAF does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Preliminary test results on spectral resolution of the Low Energy Transmission Grating Spectrometer on board of AXAF, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Preliminary test results on spectral resolution of the Low Energy Transmission Grating Spectrometer on board of AXAF will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1417186