Hard x-ray reflectivity measurement of broad-band multilayer samples

Physics – Optics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

The use of depth-graded multilayer coatings is foreseen in several future X-ray telescopes (e.g. Hexit-Sat/NHXT, NuSTAR, IXO, NeXT), in order to extend to higher energies (up to 80 keV) the focusing capabilities of present day telescopes, like Chandra and XMM/Newton, that are operative in the soft X-ray band (0.1-10 keV). The deposition of multilayer coatings is a difficult process, in which a good control of the individual layer thickness is required. The process must also be stable for the long time needed (several hours). The main issues are the accuracy of the film (stability of the process), interfacial and surface roughness, the lateral homogeneity and the long-term stability of the film. Physical properties of the film, like the density or the crystallicity are also important. The analysis of reflectivity measurements is an important tool to study the structure of multilayer samples, investigating in a non-destructive way the whole properties of the film down to the deepest layers. Nevertheless the analysis of data is not easy, neither standardized. Two samples were realized using different materials (Pt/C and W/Si). The film structures were designed to be representative of broad angular/energy band multilayer coatings foreseen in hard X-ray focusing telescopes. Their reflectivity was measured for several energies in the 40-130 keV range as a function of the reflection angle. The High energy reflectivity data are compared with the theoretical expectations derived from low-energy (8.04 keV) measures acquired after the deposition.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Hard x-ray reflectivity measurement of broad-band multilayer samples does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Hard x-ray reflectivity measurement of broad-band multilayer samples, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Hard x-ray reflectivity measurement of broad-band multilayer samples will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1302716

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.