Measurement of the magnetotail reconnection rate

Physics – Plasma Physics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

30

Magnetospheric Physics: Magnetosphere/Ionosphere Interactions, Magnetospheric Physics: Magnetospheric Configuration And Dynamics, Magnetospheric Physics: Magnetotail, Space Plasma Physics: Magnetic Reconnection

Scientific paper

A technique to measure the magnetotail reconnection rate from the ground is described and applied to 71 hours of measurements from 20 nights. The reconnection rate is obtained from the ionospheric flow across the polar cap boundary in the frame of reference of the boundary, measured by the Sondrestrom incoherent scatter radar. For our measurements, the polar cap boundary is located using 6300 Å auroral emissions and E region electron density. The average experimental uncertainty of the reconnection rate measurement is 11.6 mVm-1 in the ionospheric electric field. By using a large data set, we obtain the dependence of the reconnection rate on magnetic local time, the interplanetary magnetic field, and substorm activity, with much higher accuracy. We find that two thirds of the average polar cap potential drop occurs over the 4-hour segment of the separatrix centered on 2330 MLT, that the linear correlation between the reconnection electric field and the half-wave rectified dawn-dusk solar wind electric field VBs peaks between 1.0 and 1.5 hours, with a maximum linear correlation coefficient of 0.46 at 70 min; and that following substorm expansion phase onset, the reconnection electric field becomes larger than the experimental uncertainty, with an average delay of 23 min. The 70-min delay of the reconnection rate with respect to VBs is a typical convection time for a flux tube across the polar cap. This result indicates that reconnection in the magnetotail is influenced by the solar wind electric field VBs on the field line being reconnected.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Measurement of the magnetotail reconnection rate does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Measurement of the magnetotail reconnection rate, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Measurement of the magnetotail reconnection rate will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1119270

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.