Reconciling the centimeter- and millimeter-wavelength ammonia absorption spectra under jovian conditions: Extensive millimeter-wavelength measurements and a consistent model

Computer Science

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

1

Scientific paper

Over 1000 laboratory measurements of the 2-4 mm-wavelength opacity of ammonia have been made under simulated jovian atmospheric conditions using a high-precision laboratory system developed at Georgia Tech. These laboratory measurements of the opacity of ammonia were made of various gas mixtures of hydrogen (˜77.5-85.5%), helium (˜12.5-13.5%), and ammonia (1-10%) at pressures between 1 and 3 bars and temperatures between 200 and 300 K. Laboratory measurements were also made of the opacity of pure ammonia at pressures between 0.05 and 1 bar and temperatures between 200 and 300 K. Using these millimeter-wavelength measurements and close to 2000 cm-wavelength measurements made by Hanley et al. (2009), a new consistent model has been developed to accurately characterize the absorption spectra of ammonia in a hydrogen/helium atmosphere in the 1 mm to 30 cm wavelength range. This model can be used in the 1-30 cm wavelength range at pressures up to 20 bars and temperatures from 200 to 500 K and in the 1 mm to 1 cm wavelength range at pressures up to 3 bars and temperatures from 200 to 300 K. These measurements and the accompanying model will enable better interpretation of the centimeter- and millimeter-wavelength emission spectra of the jovian planets.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Reconciling the centimeter- and millimeter-wavelength ammonia absorption spectra under jovian conditions: Extensive millimeter-wavelength measurements and a consistent model does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Reconciling the centimeter- and millimeter-wavelength ammonia absorption spectra under jovian conditions: Extensive millimeter-wavelength measurements and a consistent model, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Reconciling the centimeter- and millimeter-wavelength ammonia absorption spectra under jovian conditions: Extensive millimeter-wavelength measurements and a consistent model will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-864553

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.