Astronomy and Astrophysics – Astrophysics
Scientific paper
1998-01-15
Astronomy and Astrophysics
Astrophysics
Presented at MRS Symposium, Boston (Dec. 1997) and to be published in "Semiconductors for Room-Temperature Radiation Detector
Scientific paper
We describe initial results of our program to develop and test Cd-Zn-Te (CZT) detectors with a pixellated array readout. Our primary interest is in the development of relatively thick CZT detectors for use in astrophysical coded aperture telescopes with response extending over the energy range $\sim 10-600$ keV. The coded aperture imaging configuration requires only relatively large area pixels (1-3 mm), whereas the desired high energy response requires detector thicknesses of at least 3-5 mm. We have developed a prototype detector employing a 10 x 10 x 5 mm CZT substrate and 4 x 4 pixel (1.5 mm each) readout with gold metal contacts for the pixels and continuous gold contact for the bias on the opposite detector face. This MSM contact configuration was fabricated by RMD and tested at Harvard for uniformity, efficiency and spatial as well as spectral resolution. We have developed an ASIC readout (IDE-VA-1) and analysis system and report results, including $\sim 4$% (FWHM) energy resolution at 60 keV. A prototype design for a full imaging detector array is discussed.
Bloser Peter F.
Grindlay Jonathon E.
Narita Taku
Shah Kushal
No associations
LandOfFree
Prototype Imaging Cd-Zn-Te Array Detector does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Prototype Imaging Cd-Zn-Te Array Detector, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Prototype Imaging Cd-Zn-Te Array Detector will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-520111