Astronomy and Astrophysics – Astrophysics
Scientific paper
2006-06-08
Astronomy and Astrophysics
Astrophysics
9 pages, 6 figures, to appear in SPIE conference proceedings vol 6276, "High Energy, Optical & Infrared Detectors for Astronom
Scientific paper
10.1117/12.669433
Thorough numerical simulations were run to test the performance of three processing methods of the data coming out from an electron multiplying charge coupled device (EMCCD), or low light level charge coupled device (L3CCD), operated at high gain, under real operating conditions. The effect of read-out noise and spurious charges is tested under various low flux conditions (0.001 event/pixel/frame < f < 20 events/pixel/frame). Moreover, a method for finding the value of the gain applied by the EMCCD amplification register is also developed. It allows one to determine the gain value to an accuracy of a fraction of a percent from dark frames alone.
Blais-Ouellette Sebastien
Carignan Claude
Daigle Olivier
No associations
LandOfFree
Faint flux performance of an EMCCD does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Faint flux performance of an EMCCD, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Faint flux performance of an EMCCD will most certainly appreciate the feedback.