Calibrating Array Detectors

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scheduled for ApJS, June 2000 (16 pages, 3 JPEG figures)

Scientific paper

10.1086/313390

The development of sensitive large format imaging arrays for the infrared promises to provide revolutionary capabilities for space astronomy. For example, the Infrared Array Camera (IRAC) on SIRTF will use four 256 x 256 arrays to provide background limited high spatial resolution images of the sky in the 3 to 8 micron spectral region. In order to reach the performance limits possible with this generation of sensitive detectors, calibration procedures must be developed so that uncertainties in detector calibration will always be dominated by photon statistics from the dark sky as a major system noise source. In the near infrared, where the faint extragalactic sky is observed through the scattered and reemitted zodiacal light from our solar system, calibration is particularly important. Faint sources must be detected on this brighter local foreground. We present a procedure for calibrating imaging systems and analyzing such data. In our approach, by proper choice of observing strategy, information about detector parameters is encoded in the sky measurements. Proper analysis allows us to simultaneously solve for sky brightness and detector parameters, and provides accurate formal error estimates. This approach allows us to extract the calibration from the observations themselves; little or no additional information is necessary to allow full interpretation of the data. Further, this approach allows refinement and verification of detector parameters during the mission, and thus does not depend on a priori knowledge of the system or ground calibration for interpretation of images.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Calibrating Array Detectors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Calibrating Array Detectors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Calibrating Array Detectors will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-482132

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.