Statistical evaluation of the flux cross-calibration of the XMM-Newton EPIC cameras

Astronomy and Astrophysics – Astrophysics – Instrumentation and Methods for Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

11 pages, 10 figures, 3 tables. Abridged Abstract. Accepted for publication in Astronomy and Astrophysics

Scientific paper

10.1051/0004-6361/200811409

The second XMM-Newton serendipitous source catalogue, 2XMM, provides the ideal data base for performing a statistical evaluation of the flux cross-calibration of the XMM-Newton European Photon Imaging Cameras (EPIC). We aim to evaluate the status of the relative flux calibration of the EPIC cameras on board XMM-Newton (MOS1, MOS2, and pn) and investigate the dependence of the calibration on energy, position in the field of view of the X-ray detectors, and lifetime of the mission. We compiled the distribution of flux percentage differences for large samples of 'good quality' objects detected with at least two of the EPIC cameras. The mean offset of the fluxes and dispersion of the distributions was then found by Gaussian fitting. Count rate to flux conversion was performed with a fixed spectral model. The impact on the results of varying this model was investigated. Excellent agreement was found between the two EPIC MOS cameras to better than 4% from 0.2 keV to 12.0 keV. MOS cameras register 7-9% higher flux than pn below 4.5 keV and 10-13% flux excess above 4.5 keV. No evolution of the flux ratios is seen with time, except at energies below 0.5 keV, where we found a strong decrease in the MOS to pn flux ratio with time. This effect is known to be due to a gradually degrading MOS redistribution function. The flux ratios show some dependence on distance from the optical axis in the sense that the MOS to pn flux excess increases with off-axis angle. Furthermore, in the 4.5-12.0 keV band there is a strong dependence of the MOS to pn excess flux on the azimuthal-angle. These results strongly suggest that the calibration of the Reflection Grating Array (RGA) blocking factors is incorrect at high energies. Finally, we recommend ways to improve the calculation of fluxes in future versions of XMM-Newton source catalogues.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Statistical evaluation of the flux cross-calibration of the XMM-Newton EPIC cameras does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Statistical evaluation of the flux cross-calibration of the XMM-Newton EPIC cameras, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Statistical evaluation of the flux cross-calibration of the XMM-Newton EPIC cameras will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-372284

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.