Tropospheric Phase Calibration in Millimeter Interferometry

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

AAS LATEX preprint format. to appear in Radio Science 1999

Scientific paper

We review millimeter interferometric phase variations caused by variations in the precipitable water vapor content of the troposphere, and we discuss techniques proposed to correct for these variations. We present observations with the Very Large Array at 22 GHz and 43 GHz designed to test these techniques. We find that both the Fast Switching and Paired Array calibration techniques are effective at reducing tropospheric phase noise for radio interferometers. In both cases, the residual rms phase fluctuations after correction are independent of baseline length for b > b_{eff}. These techniques allow for diffraction limited imaging of faint sources on arbitrarily long baselines at mm wavelengths. We consider the technique of tropospheric phase correction using a measurement of the precipitable water vapor content of the troposphere via a radiometric measurement of the brightness temperature of the atmosphere. Required sensitivities range from 20 mK at 90 GHz to 1 K at 185 GHz for the MMA, and 120 mK for the VLA at 22 GHz. The minimum gain stability requirement is 200 at 185 GHz at the MMA assuming that the astronomical receivers are used for radiometry. This increases to 2000 for an uncooled system. The stability requirement is 450 for the cooled system at the VLA at 22 GHz. To perform absolute radiometric phase corrections also requires knowledge of the tropospheric parameters and models to an accuracy of a few percent. It may be possible to perform an `empirically calibrated' radiometric phase correction, in which the relationship between fluctuations in brightness temperature differences with fluctuations in interferometric phases is calibrated by observing a celestial calibrator at regular intervals.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Tropospheric Phase Calibration in Millimeter Interferometry does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Tropospheric Phase Calibration in Millimeter Interferometry, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Tropospheric Phase Calibration in Millimeter Interferometry will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-328567

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.