Gamma-ray burst detection with the AGILE mini-calorimeter

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

6 pages, 7 figures, accepted for publication by A&A 13/08/2008

Scientific paper

10.1051/0004-6361:200810562

The Mini-Calorimeter (MCAL) instrument on-board the AGILE satellite is a non-imaging gamma-ray scintillation detector sensitive in the 300keV-100MeV energy range with a total on-axis geometrical area of 1400cm^2. Gamma-Ray Bursts (GRBs) are one of the main scientific targets of the AGILE mission and the MCAL design as an independent self-triggering detector makes it a valuable all-sky monitor for GRBs. Furthermore MCAL is one of the very few operative instruments with microsecond timing capabilities in the MeV range. In this paper the results of GRB detections with MCAL after one year of operation in space are presented and discussed. A flexible trigger logic implemented in the AGILE payload data-handling unit allows the on-board detection of GRBs. For triggered events, energy and timing information are sent to telemetry on a photon-by-photon basis, so that energy and time binning are limited by counting statistics only. When the trigger logic is not active, GRBs can be detected offline in ratemeter data, although with worse energy and time resolution. Between the end of June 2007 and June 2008 MCAL detected 51 GRBs, with a detection rate of about 1 GRB/week, plus several other events at a few milliseconds timescales. Since February 2008 the on-board trigger logic has been fully active. Comparison of MCAL detected events and data provided by other space instruments confirms the sensitivity and effective area estimations. MCAL also joined the 3rd Inter-Planetary Network, to contribute to GRB localization by means of triangulation.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Gamma-ray burst detection with the AGILE mini-calorimeter does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Gamma-ray burst detection with the AGILE mini-calorimeter, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Gamma-ray burst detection with the AGILE mini-calorimeter will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-327045

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.