Self-Calibration Technique for 3-point Intrinsic Alignment Correlations in Weak Lensing Surveys

Astronomy and Astrophysics – Astrophysics – Cosmology and Extragalactic Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

22 pages, 5 figures, matches version published in MNRAS. Published online December 5, 2011

Scientific paper

The intrinsic alignment (IA) of galaxies has been shown to be a significant barrier to precision cosmic shear measurements. (Zhang, 2010, ApJ, 720, 1090) proposed a self-calibration technique for the power spectrum to calculate the induced gravitational shear-galaxy intrinsic ellipticity correlation (GI) in weak lensing surveys with photo-z measurements which is expected to reduce the IA contamination by at least a factor of 10 for currently proposed surveys. We confirm this using an independent analysis and propose an expansion to the self-calibration technique for the bispectrum in order to calculate the dominant IA gravitational shear-gravitational shear-intrinsic ellipticity correlation (GGI) contamination. We first establish an estimator to extract the galaxy density-density-intrinsic ellipticity (ggI) correlation from the galaxy ellipticity-density-density measurement for a photo-z galaxy sample. We then develop a relation between the GGI and ggI bispectra, which allows for the estimation and removal of the GGI correlation from the cosmic shear signal. We explore the performance of these two methods, compare to other possible sources of error, and show that the GGI self-calibration technique can potentially reduce the IA contamination by up to a factor of 5-10 for all but a few bin choices, thus reducing the contamination to the percent level. The self-calibration is less accurate for adjacent bins, but still allows for a factor of three reduction in the IA contamination. The self-calibration thus promises to be an efficient technique to isolate both the 2-point and 3-point intrinsic alignment signals from weak lensing measurements.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Self-Calibration Technique for 3-point Intrinsic Alignment Correlations in Weak Lensing Surveys does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Self-Calibration Technique for 3-point Intrinsic Alignment Correlations in Weak Lensing Surveys, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Self-Calibration Technique for 3-point Intrinsic Alignment Correlations in Weak Lensing Surveys will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-263653

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.