Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase A Study

Astronomy and Astrophysics – Astrophysics – Instrumentation and Methods for Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

6 pages, 3 figures, invited talk at the conference "2nd International Simbol-X Symposium", Paris, 2-5 december, 2008

Scientific paper

10.1063/1.3149454

Simbol-X will push grazing incidence imaging up to 80 keV, providing a strong improvement both in sensitivity and angular resolution compared to all instruments that have operated so far above 10 keV. The superb hard X-ray imaging capability will be guaranteed by a mirror module of 100 electroformed Nickel shells with a multilayer reflecting coating. Here we will describe the technogical development and solutions adopted for the fabrication of the mirror module, that must guarantee an Half Energy Width (HEW) better than 20 arcsec from 0.5 up to 30 keV and a goal of 40 arcsec at 60 keV. During the phase A, terminated at the end of 2008, we have developed three engineering models with two, two and three shells, respectively. The most critical aspects in the development of the Simbol-X mirrors are i) the production of the 100 mandrels with very good surface quality within the timeline of the mission; ii) the replication of shells that must be very thin (a factor of 2 thinner than those of XMM-Newton) and still have very good image quality up to 80 keV; iii) the development of an integration process that allows us to integrate these very thin mirrors maintaining their intrinsic good image quality. The Phase A study has shown that we can fabricate the mandrels with the needed quality and that we have developed a valid integration process. The shells that we have produced so far have a quite good image quality, e.g. HEW <~30 arcsec at 30 keV, and effective area. However, we still need to make some improvements to reach the requirements. We will briefly present these results and discuss the possible improvements that we will investigate during phase B.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase A Study does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase A Study, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase A Study will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-235527

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.