Evaluation of the Performance of the Mars Environmental Compatibility Assessment Electrometer

Computer Science – Performance

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Evaluation, Performance Prediction, Electrometers, Ionization Gages, Mars Atmosphere, Temperature Sensors, Charged Particles, Compatibility, Electric Field Strength, Electric Fields, Electrostatics, Insulators

Scientific paper

The Mars Environmental Compatibility Assessment (MECA) electrometer is an instrument that was designed jointly by researchers at the Jet Propulsion Laboratory and the Kennedy Space Center, and is intended to fly on a future space exploration mission of the surface of Mars. The electrometer was designed primarily to study (1) the electrostatic interaction between the Martian soil and five different types of insulators, which are attached to the electrometer, as the electrometer is rubbed over the Martian soil. The MECA/Electrometer is also capable of measuring (2) the presence of charged particles in the Martian atmosphere, (3) the local electric field strength, and (4) the local temperature. The goal of the research project described in this report was to test and evaluate the measurement capabilities of the MECA/Electrometer under simulated Martian surface conditions using facilities located in the Labs and Testbeds Division at the Kennedy Space Center. The results of this study indicate that the Martian soil simulant can triboelectrically charge up the insulator surface. However, the maximum charge buildup did not exceed 18% of the electrometer's full-range sensitivity when rubbed vigorously, and is more likely to be as low as 1% of the maximum range when rubbed through soil. This indicates that the overall gain of the MECA/Electrometer could be increased by a factor of 50 if measurements at the 50% level of full-range sensitivity are desired. The ion gauge, which detects the presence of charged particles, was also evaluated over a pressure range from 10 to 400 Torr (13 to 533 mbar). The electric field sensor was also evaluated. Although the temperature sensor was not evaluated due to project time constraints, it was previously reported to work properly.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Evaluation of the Performance of the Mars Environmental Compatibility Assessment Electrometer does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Evaluation of the Performance of the Mars Environmental Compatibility Assessment Electrometer, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Evaluation of the Performance of the Mars Environmental Compatibility Assessment Electrometer will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1893536

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.