X-ray Microlensing in RXJ1131-1231 and HE1104-1805

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Comments: 23 pages, includes 12 figures, revised version, corrected figure, accepted for publication in ApJ

Scientific paper

10.1088/0004-637X/693/1/174

We present results from a monitoring campaign performed with the Chandra X-ray Observatory of the gravitationally lensed quasars RX J1131-1231 and HE 1104-1805. We detect significant X-ray variability in all images of both quasars. The flux variability detected in image A of RX J1131-1231 is of particular interest because of its high amplitude (a factor of ~ 20). We interpret it as arising from microlensing since the variability is uncorrelated with that of the other images and the X-ray flux ratios show larger changes than the optical as we would expect for microlensing of the more compact X-ray emission regions. The differences between the X-ray and optical flux ratios of HE 1104-1805 are less dramatic, but there is no significant soft X-ray or dust absorption, implying the presence of X-ray microlensing in this system as well. Combining the X-ray data with the optical light curves we find that the X-ray emitting region of HE 1104-1805 is compact with a half-light radius ~ 6 r_g, where the gravitational radius is r_g = 3.6 x 10^14 cm, thus placing significant constraints on AGN corona models. We also find that the microlensing in HE 1104-1805 favors mass models for the lens galaxy that are dominated by dark matter. Finally, we better characterize the massive foreground cluster near RX J1131-1231, set limits on other sources of extended X-ray emission, and limit the fluxes of any central odd images to be 30-50 (3 sigma) times fainter than the observed images.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

X-ray Microlensing in RXJ1131-1231 and HE1104-1805 does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with X-ray Microlensing in RXJ1131-1231 and HE1104-1805, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and X-ray Microlensing in RXJ1131-1231 and HE1104-1805 will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-179161

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.