Soft x-ray spectroscopy using charge-coupled devices with thin poly gates and floating gate output amplifiers

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

We present data from a charge-coupled device (CCD), collaboratively designed by PSU/JPL/Loral, which incorporates several novel features that make it well suited for soft X-ray spectroscopy. It is a three-phase, front-side illuminated device with 1024x1024 pixels. Each pixel is 18 microns by 18 microns.The device has four output amplifiers: two conventional floating diffusion amplifiers (FDAs) and two floating gate amplifiers (FGAs). The FGA non-destructively samples the output charge, allowing the charge in each pixel to be measured multiple times. The readnoise of a given pixel is reduced as the square root of the number of readouts, allowing one to reduce the amplifier noise of these devices to well below the 1/f knee. We have been able to achieve sub-electron readnoise performance with the floating gate amplifier (0.9 e+-) rms with 16 reads per pixel). Using the FGA, the measured energy resolution at 5.9 keV is 120 eV (FWHM). The CCD also has a thin poly gate structure to maximize soft X-ray quantum efficiency. Two-thirds of the active area of the chip is covered only by an insulating layer (1000 angstrom) and a thin poly silicon electrode (400 angstrom). This design enhances the soft X-ray quantum efficiency, but retains the excellent charge transfer efficiency and soft X-ray charge collection efficiency of front-side illuminated devices. The measured energy resolution at 277 eV is 38 eV (FWHM) with a measured quantum efficiency of 15%. We also show that this device performs well below 100 eV, as demonstrated by the detection of Al L fluorescence at 72 eV with a measured FWHM of 16 eV.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Soft x-ray spectroscopy using charge-coupled devices with thin poly gates and floating gate output amplifiers does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Soft x-ray spectroscopy using charge-coupled devices with thin poly gates and floating gate output amplifiers, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Soft x-ray spectroscopy using charge-coupled devices with thin poly gates and floating gate output amplifiers will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1713450

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.