Use of the very large array for measurement of time variable Faraday rotation

Mathematics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

8

Calibrating, Faraday Effect, Instrument Errors, Polarized Light, Time Measurement, Very Large Array (Vla), Mathematical Models, Remote Sensing, Rotation, Time Series Analysis

Scientific paper

In this paper we present a method for applying a second-order correction to the polarization data taken at the very large array (VLA). We found that the standard polarization calibration method is inadequate for obtaining a polarization angle time series with position angle constancy better than a few degrees over several hours. Even after application of a more sophisticated ionospheric Faraday rotation model than is commonly employed in VLA polarization measurements, the rms scatter in position angle exceeded 2 deg at 20 cm. In order to reduce this scatter, a polarization 'self-calibration' method was developed to correct the data for residual instrumental polarization, here noted by the array-averaged instrumental polarization error A to be defined and discussed in section 5, and ionospheric Faraday rotation errors delta theta(sub FR). Using four extragalactic radio sources with fractional polarization ranging from 1 to 4.8%, the residual errors A and delta theta(sub FR) were estimated. A typical value of A was 10(exp - 3) and the magnitude of delta theta(sub FR) was less than 2 deg. These residuals, however, are enough to limit the VLA polarization angle measurement to roughly 2 deg at 20 cm. The instrumental polarization error was found to be time variable with a timescale of a few hours. These errors were removed from the data, and the corrected data showed an improvement in polarization time series with a smaller scatter in position angle, except for the source 0010 + 005. It was close to the Sun on the day of the observation, and we believe the excess fluctuations are due to coronal plasma turbulence. We believe the technique described in this paper will be of use to observations in which the Faraday rotation varies during the course of an observing session, such as measurements of coronal Faraday rotation, or in which it is important to eliminate or minimize the Faraday rotation noise. An example of the latter type of observation would be the study of pulsar rotation measure variations over long time intervals. Of course, a result of this procedure is a precision determination of ionospheric rotation measure, in principle in various directions. Such observations might aid radio remote sensing studies of the ionosphere.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Use of the very large array for measurement of time variable Faraday rotation does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Use of the very large array for measurement of time variable Faraday rotation, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Use of the very large array for measurement of time variable Faraday rotation will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1681037

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.