Computer Science – Performance
Scientific paper
May 1974
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1974stin...7525291k&link_type=abstract
Unknown
Computer Science
Performance
Apollo Telescope Mount, Nickel Cadmium Batteries, Spacecraft Power Supplies, Electric Potential, Performance Tests, Solar Arrays, Storage Batteries
Scientific paper
The operational testing and evaluation program is presented which was conducted on 20-ampere-hour nickel-cadmium (Ni-Cd) batteries for use on the Apollo telescope mount (ATM). The test program was initiated in 1967 to determine if the batteries could meet ATM mission requirements and to determine operating characteristics and methods. The ATM system power and charging power for the Ni-Cd secondary batteries is provided by a solar array during the 58-minute daylight portion of the orbit; during the 36-minute night portion of the orbit, the Ni-Cd secondary batteries will supply ATM system power. The test results reflect battery operating characteristics and parameters relative to simulated ATM orbital test conditions. Maximum voltage, charge requirements, capacity, temperature, and cyclic characteristics are presented.
Kirsch Werner
Shikoh A. E.
No associations
LandOfFree
Nickel-cadium batteries for Apollo telescope mount does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Nickel-cadium batteries for Apollo telescope mount, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Nickel-cadium batteries for Apollo telescope mount will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1597746