The dark current and readout noise levels for WFC3's UVIS channel were tested during thermal vacuum testing in September and October, 2004. Measured readnoise values were comparable to those measured during mini-ambient testing (Baggett, 2004 and Hilbert et al., 2004), below the CEI specification of 4 e-, and just above the goal of 3 e-. Measured RMS dark currents were 0.16 - 0.5 e-/pix/hour, lower than those from mini-ambient testing, and well below the CEI specification of 20 e-/pix/hour.
Baggett Sylvia
Hilbert Bryan
No associations
LandOfFree
Results of WFC3 Thermal Vacuum Testing: UVIS Readnoise and Dark Current does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Results of WFC3 Thermal Vacuum Testing: UVIS Readnoise and Dark Current, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Results of WFC3 Thermal Vacuum Testing: UVIS Readnoise and Dark Current will most certainly appreciate the feedback.