Appendix: Limits on the use of heterodyning and amplification in optical interferometry

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Amplification, Heterodyning, Infrared Radiation, Noise Temperature, Optical Fibers, Very Long Base Interferometry, Astronomy, Background Noise, Photons, Quantum Mechanics, Radio Frequencies, Spontaneous Emission, Stimulated Emission, Synthetic Apertures, Thermodynamics

Scientific paper

The development of optical fibers, lasers, and mixers at optical frequencies has offered the hope that active methods can contribute to optical interferometry. Heterodyning, in particular, looks attractive, even though bandwidths are narrower than one would like at present; one might expect this limitation to lessen as technology develops. That expectation, unfortunately, is not likely to benefit interferometry at optical wavelengths because of the intervention of quantum mechanics and the second law of thermodynamics, as Burke (1985a) pointed out. So much 'second quantization' noise is generated that only at infrared frequencies, somewhere in the 10-100 micron range, can one look forward to heterodyning in any realistic sense. The reason is easily understood. Every amplifier, in the quantum limit, works by stimulated emission, even though this basic truth is not obvious at radio frequencies. This means that there must be spontaneous emission occurring within every amplifier, and Strandberg (1957) showed that this implied a limiting noise temperature, TN = h nu/k, for any amplifier. Burke (1969) used this result to demonstrate that, if it were not for this quantum noise, the VLBI method would allow one to tell which slit a photon went through before forming an interference pattern, thus violating basic tenants of quantum mechanics. In essence, the second quantization condition Delta N Delta phi greater than or = 1 saves one from paradox. One can state the conclusion simply: any amplifier produces approximately one photon per Hertz of bandwidth. In optical interferometry, one will certainly want bandwidth in the 1012 to 1014 Hz range, and that implies an intolerable cacophony of noise photons. Only at infrared frequencies can one tolerate the quantum noise, where the natural noise background may be high and the mixers are not as efficient as one would hope for. The crossover at present is about 10 or 20 microns, but the boundary will shift to longer wavelengths as noise performance improves. One might guess that ultimately a wavelength of about 100 microns will mark the limit of useful amplification and heterodyning in astronomical aperture synthesis interferometry.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Appendix: Limits on the use of heterodyning and amplification in optical interferometry does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Appendix: Limits on the use of heterodyning and amplification in optical interferometry, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Appendix: Limits on the use of heterodyning and amplification in optical interferometry will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1554944

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.