Mid-infrared observations of photodissociation regions and MIRSI: A Mid-infraRed Spectrometer and Imager developed for ground based observing

Computer Science – Performance

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

2

Scientific paper

The structure of high-mass, star-forming cloud complexes containing photodissociation regions (PDRs) viewed edge- on is examined through 8.7 20.6 μm images and 8 13 μm spectra. For a homogeneous, neutral cloud illuminated by a bright OB star, PDR theory predicts that the ultra-violet (UV) radiation is attenuated exponentially (e-1.8Aν). The predicted UV attenuation is confirmed by observations of broad emission features found at 8.6, 11.2, and 12.7 μm, commonly attributed to emission from polycyclic aromatic hydrocarbons (PAHs). The PAH emission is located between the edges of HII regions and layers of [CI] emission, agreeing with PDR theory. By modeling the spatial variations in the emission from ionized gas and PAHs, the geometry of the PDR and the gas density are determined. With constraints placed on the geometry of the PDR, PAHs must be destroyed almost instantaneously or not at all inside HII regions, disagreeing with previous determinations. According to PAH theory, the transition from ionized to neutral PAHs at PDR surfaces is traceable by the relative strengths of the PAH features. On large and small size scales, the relative strengths of the 8.6, 11.2, and 12.7 μm PAH features at the bar of the Orion Nebula indicate that there is not a simple transition from ionized to neutral PAHs across the PDR. Over half of the observations presented were acquired with a Mid-InfraRed Spectrometer and Imager, MIRSI, completed at Boston University and currently operating at the NASA InfraRed Telescope Facility (IRTF). MIRSI utilizes the largest available mid-infrared array (320 x 240) developed by Raytheon/Santa Barbara Research Corporation for ground-based infrared applications. MIRSI's advantage at the IRTF is a wide field of view (85″ x 64″) with diffraction limited imaging (0.7″ at 10 μm with a 0.27″ pixel scale). MIRSI switches between spectroscopic and imaging modes in a minute, enabling quick association of the spatial and spectral emission components. Meeting the camera's design goals, a one sigma detection with MIRSI at 10 μm (47% bandpass) is four mJy for an on-source exposure time of one minute. At Boston University, I wrote software to interface the host computer with hardware components, designed and fabricated mechanical and electrical components, and optimized and characterized MIRSI's performance.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Mid-infrared observations of photodissociation regions and MIRSI: A Mid-infraRed Spectrometer and Imager developed for ground based observing does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Mid-infrared observations of photodissociation regions and MIRSI: A Mid-infraRed Spectrometer and Imager developed for ground based observing, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Mid-infrared observations of photodissociation regions and MIRSI: A Mid-infraRed Spectrometer and Imager developed for ground based observing will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1461124

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.