Flux Calibration of the STIS CCD: Correcting for Charge Transfer Inefficiency and Time-Dependent Sensitivity

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

A variety of on-orbit imaging and spectroscopic observations have been used to characterize the Charge Transfer Efficiency (CTE) of the Charge-Coupled Device (CCD) of the Space Telescope Imaging Spectrograph (STIS) aboard the Hubble Space Telescope. A set of formulae has been developed to correct aperture photometry and spectrophotometry of point sources for CTE-related loss, with dependencies on X and Y positions, the source signal, the background counts, and the time of observation. Application of the new formulae leads to a CCD flux calibration that is accurate to within one percent, independent of source signal.
The analysis of the STIS Sensitivity Monitor observations from 1997 through January 2003 shows continuing sensitivity trends correlated with time for all first-order, low- and medium resolution spectroscopic modes as well as a temperature dependance in the FUV and recently in the CCD detectors. The newly available CTE corrections allow for the proper determination of time-dependent sensitivity (TDS) trends in CCD modes. The wavelength-averaged rates of sensitivity loss for the CCD modes range from 0%/yr (G750L grating) to 1.5%/yr (G230LB grating). These sensitivity losses are wavelength dependent and will be corrected for within the STIS data reduction pipeline by means of the delivery of new reference files.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Flux Calibration of the STIS CCD: Correcting for Charge Transfer Inefficiency and Time-Dependent Sensitivity does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Flux Calibration of the STIS CCD: Correcting for Charge Transfer Inefficiency and Time-Dependent Sensitivity, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Flux Calibration of the STIS CCD: Correcting for Charge Transfer Inefficiency and Time-Dependent Sensitivity will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1366752

  Search