Astronomy and Astrophysics – Astrophysics
Scientific paper
Sep 2009
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2009a%26a...504..663c&link_type=abstract
Astronomy and Astrophysics, Volume 504, Issue 2, 2009, pp.663-671
Astronomy and Astrophysics
Astrophysics
4
Instrumentation: High Angular Resolution, Methods: Laboratory, Techniques: High Angular Resolution, Techniques: Interferometric
Scientific paper
Aims: We report results obtained with a four-quadrant and an eight-octant phase-mask coronagraphs (4QC and 8OC) produced using amplitude masks inside a Mach-Zehnder interferometer (MZI). We describe the laboratory implementation of these coronagraphs operated in laser light and provide a detailed comparison between theory and experiment. Methods: The +1 and -1 (π phase) amplitude transmissions required to produce a 4QC or an 8OC were obtained using complementary binary-masks (transmission of 1 or 0 for quadrants of similar parities) in the two arms of a MZI, taking advantage of the achromatic π phase shift between the two paths. In one output of the MZI, the reconstructed image of the focal plane is similar to those obtained for sectorised phase-masks coronagraphs, and the image of the aperture corresponds to the characteristic patterns of the 4QC/8OC coronagraphs. Results: Observations are compared with the theory published by other authors and developed further here. The expressions for the light diffracted outside the aperture image are simplified using the Zernike radial polynomials Z1n instead of the rapidly diverging hypergeometric functions otherwise used. Experimental results are found to be in very good agreement with the theory. With the present laboratory experiment, about 99% of the light is rejected outside the Lyot stop and the contrast obtained beyond 5 λ/D is higher than 105 for both the 4QC and 8OC. As expected, the 8OC is less affected by a pointing error than the 4QC, but more sensitive to an aperture central obstruction. Incidently, the loss of transmission for a planet crossing two phase masks is given theoretically as a function of the Lyot stop size, in agreement with observations.
Aime Claude
Carlotti Alexis
Ricort Gilbert
No associations
LandOfFree
Phase mask coronagraphy using a Mach-Zehnder interferometer does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Phase mask coronagraphy using a Mach-Zehnder interferometer, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Phase mask coronagraphy using a Mach-Zehnder interferometer will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1271172