Instant Stereoscopic Tomography of Active Regions with STEREO/EUVI

Statistics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

7509 Corona, 7524 Magnetic Fields, 7549 Ultraviolet Emissions

Scientific paper

We develop a novel 3D reconstruction method of the coronal plasma of an active region by combining stereoscopic triangulation of loops with density and temperature modeling of coronal loops with a filling factor equivalent to tomographic volume rendering. Because this method requires only a stereoscopic image pair in multiple temperature filters, which are sampled within ~1 minute with the recent STEREO/EUVI instrument, this method is about 4 orders of magnitude faster than conventional solar rotation-based tomography. We reconstruct the 3D density and temperature distribution of active region NOAA 10955 by stereoscopic triangulation of 70 loops, which are used as a skeleton for a 3D field interpolation of some 7000 loop components, leading to a 3D model that reproduces the observed fluxes in each stereosocpic image pair with an accuracy of a few percent (of the average flux) in each pixel. With the stereoscopic tomography we infer also a differential emission measure (DEM) distribution over the entire temperature range of T~0.01-10 MK, with predictions for the transition region and hotter corona in soft X-rays. The tomographic 3D model provides also large statistics of physical parameters. We find that the EUV loops with apex temperatures of T = 1- 3 MK tend to be super-hydrostatic, while hotter loops with T = 4-7 MK are near-hydrostatic. The new 3D reconstruction model is fully independent of any magnetic field data and is promising for future tests of theoretical magnetic field models and coronal heating models.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Instant Stereoscopic Tomography of Active Regions with STEREO/EUVI does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Instant Stereoscopic Tomography of Active Regions with STEREO/EUVI, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Instant Stereoscopic Tomography of Active Regions with STEREO/EUVI will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1246668

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.