Estimation of the Appropriate Length Scale to Use with the Quench Level Approximation for Obtaining Chemical Abundances

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

The ``quench level'' approximation for estimating the observed abundance of chemically reacting species in the presence of convective dynamics states that the chemical reaction is quenched at the level where the time scales for the chemical reaction and for convective dynamics are equal. The dynamical time constant, tdyn, can be computed using tdyn=L(2/K) , where L is a length scale and K is the vertical eddy diffusion coefficient. Usually K is left as a free parameter, and lacking any better information, L is taken to be a scale height. Here we show that the length scale, L, can be estimated by comparing the results of three different simple mathematical ``models'' for convective dynamics. Each of the three models uses a different fundamental quantity in describing the strength or efficiency of mixing that depends on the unknown length scale, L, in a different way. By demanding that the three models give consistent results, we arrive at an independent estimate of L. We find that the appropriate value of L is different for different chemical reactions, and can be far from a scale height. As an example, we find that L=0.14 scale heights is appropriate for the estimation of the isotopic enrichment of (D/H) in CH_4 over (D/H) in H_2. Using L=0.14 scale heights leads to a value of 1.17 on Jupiter at a typical value of K=10(8) cm(2) sec(-1) compared to 1.21 when L=1.0 scale heights is used. This indicates that greater care should be taken when using the quench level approximation to estimate chemical abundances.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Estimation of the Appropriate Length Scale to Use with the Quench Level Approximation for Obtaining Chemical Abundances does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Estimation of the Appropriate Length Scale to Use with the Quench Level Approximation for Obtaining Chemical Abundances, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Estimation of the Appropriate Length Scale to Use with the Quench Level Approximation for Obtaining Chemical Abundances will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1188365

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.