Evaluation and modification of commercial infra-red transducers for leaf temperature measurement

Other

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

12

Scientific paper

Accurate measurement of the leaf to air temperature gradient is crucial for the determination of stomatal conductance and other plant responses in both single leaves and in plant canopies. This gradient is often less than 1 ° C, which means that leaf temperature must be known to within about +/-0.1 ° C. This is a challenging task, but new, miniature infra-red transducers from Exergen Corporation (Newton, MA) and Everest Interscience (Tucson, AZ) can be modified and calibrated to achieve this accuracy. The sensors must be modified to add thermal mass and the Exergen sensor requires a measurement of sensor body temperature. Significant error is caused by the discharge of a capacitor in the standard Exergen sensor, but we tested it without the capacitor. The sensors respond rapidly to changes in target temperature, but require 2 to 10 minutes to respond to changes in sensor body temperature, which is often the largest source of error. A new, sensitive method for measuring field of view indicates substantial peripheral vision for both sensors and a wider field of view than specified by the manufacturers. Here we describe sensor output as a function of target and sensor body temperatures, and provide a generic (sensor independent) equation that can be used to achieve +/-0.2 C accuracy with Exergen sensors. The equation was developed and verified using two black body calibrators.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Evaluation and modification of commercial infra-red transducers for leaf temperature measurement does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Evaluation and modification of commercial infra-red transducers for leaf temperature measurement, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Evaluation and modification of commercial infra-red transducers for leaf temperature measurement will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1074001

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.