Kinetics and equilibria of redox systems at temperatures as low as 300°C

Other

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

2

Scientific paper

ZrO 2 oxygen sensors, gas mixtures, and conventional solid buffers have been used for decades to either control or measure oxygen fugacity ( f O 2 ) at high temperatures. In dry systems below ca. 700°C these techniques were used cautiously, if at all, due to doubt that there was any equilibration at lower temperatures. We have re-investigated these three types of redox systems in a study where each system (two different Y 2 O 3 -ZrO 2 cells, four different gas mixtures, and four different dry solid buffers) was simultaneously cross-checked with the other to temperatures below 300°C and compared to JANAF data, extrapolated down to low temperatures. Steady and reproducible readings were observed down to T 300°C, from which we infer fast kinetics for all three systems. Specifically, we find equilibration of various CO 2 -H 2 gas mixtures over the entire temperature range and to much lower temperature than previously predicted. We assign the reactivity (decomposition) of CO 2 at low T to the catalytic action of Pt, whereby chemisorption of H 2 on the platinum surface enhances the reactivity with CO 2 . This catalytic reactivity is diminished over time due to a long-term irreversible reaction of Pt with H 2 . Subsequent embrittling and aging after prolonged exposure to H 2 explains erroneously high emf readings. Oxygen sensing of ZrO 2 cells is linear in O 2 space and Nernstian at high temperatures. However, for cells with a specific and complex trace element chemistry, one may observe a non-Nernstian behavior in the low T range, i.e., below 470° or lower, probably caused by partially blocked O 2- migration, dependent on the H 2 content in the gas mixture. Linearity and reproducibility of this deviation still allows, however, a useable calibration. Solid buffers of the metal-metal oxide type are known to alloy with noble metals and we therefore used AgPd electrodes, for consistency in all studies, including (IW), (IM), (FMQ), and (NNO). Whereas (IW) and (IM) can be used in the temperature range of consideration, (FMQ) and (NNO) react sluggishly. Complex defect structure of (FMQ) and age alteration of Ni surfaces by chemisorption of oxygen and/or Ag-Ni alloying of (NNO) may be the reason. Fast kinetics and successful redox sensing of CO 2 -H 2 gas mixtures, of ZrO 2 cells and of at least some solid buffers are therefore promising for future research on low- T redox equilibria.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Kinetics and equilibria of redox systems at temperatures as low as 300°C does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Kinetics and equilibria of redox systems at temperatures as low as 300°C, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Kinetics and equilibria of redox systems at temperatures as low as 300°C will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1060333

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.