MERIS O2 Calibration using SCIAMACHY Measurements

Other

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

A new MERIS spectral calibration method is proposed exploiting the synergy between MERIS and SCIAMACHY ENVISAT instruments. Detailed method description and preliminary results are presented in this paper. In the O2 calibration mode MERIS is measuring atmospheric radiances in the 750-780 nm spectral range in order to verify the instrument ability to reproduce position and shape of O2 band-A absorption features. The same spectral range is covered by SCIAMACHY, although at different space and spectral resolution. When operated in this mode the MERIS slit functions are characterized by a FWHM of 1.2 nm, while for SCIAMACHY the spectral resolution is 0.3 nm. Ground pixel size for MERIS and SCIAMACHY are respectively 1.1x1.3 and 30x40 km2. The proposed method is based on the assumption that the two instruments are probing the same atmosphere and, hence, detected spectral features are approximately the same. Moreover, it assumes SCIAMACHY spectral calibration to be stable and very accurate. Nevertheless, this method can be used adopting other independent sources of oxygen data as reference for the inter comparison with MERIS spectra (e.g. GOME spectral measurements, HITRAN spectral database). The estimated shift refers to the entire wavelength range and not a single MERIS band. Preliminary results indicate that this simple method can efficiently detect MERIS wavelength shifts with respect to SCIAMACHY (or to any other reference spectral database) with an accuracy of 0.01 nm along the orbit, allowing for global analysis.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

MERIS O2 Calibration using SCIAMACHY Measurements does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with MERIS O2 Calibration using SCIAMACHY Measurements, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and MERIS O2 Calibration using SCIAMACHY Measurements will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1058050

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.