X-ray pulse-shape analysis on bridge-type microcalorimeters with Ti-Au transition-edge sensors

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

We have fabricated a bridge-type structure for microcalorimeters with superconducting transition-edge sensors (TES). Instead of open space under a SiNx membrane in conventional TES microcalorimeters, the bridge-type calorimeters have SiNx membrane floating on the Si substrate covered by a SiO2 layer with a small gap of 30 - 50 micrometer. The bridge-type structure ensures that the calorimeters are mechanically tough. In addition, the thermal conductance can easily be controlled by changing the width, length, or thickness of the SiNx bridge. The calorimeters, of which operating temperature is 0.43 K, consist of a Ti/Au bilayer TES and an Au absorber. The x-ray events were read out by a DC-SQUID current amplifier with a 200-series array of SQUIDs placed on a 4.2 K stage. By analyzing the output pulse shapes, it has been found that the pulses are put into two categories. One has a fast rise time of approximately 3 microseconds and two decay components with time constants of approximately 10 microseconds and about approximately 130 microseconds. Another one has a longer rise time of approximately 10 microseconds and a single decay component of approximately 130 microseconds. It is considered that the pulse shapes depend on the x-ray absorption positions and the heat-flow pass.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

X-ray pulse-shape analysis on bridge-type microcalorimeters with Ti-Au transition-edge sensors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with X-ray pulse-shape analysis on bridge-type microcalorimeters with Ti-Au transition-edge sensors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and X-ray pulse-shape analysis on bridge-type microcalorimeters with Ti-Au transition-edge sensors will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1161438

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.