The UVIS imaging performance over the detector will be assessed periodically {every 4 months} in two passbands {F275W and F621M} to check for image stability. The field around star 58 in the open cluster NGC188 is the chosen target because it is sufficiently dense to provide good sampling over the FOV while providing enough isolated stars to permit accurate PSF {point spread function} measurement. It is available year-round and used previously for ACS image quality assessment. The field is astrometric, and astrometric guide stars will be used, so that the plate scale and image orientation may also be determined if necessary {as in SMOV proposals 11436 and 11442}. Full frame images will be obtained at each of 4 POSTARG offset positions designed to improve sampling over the detector. This proposal is a periodic repeat {once every 4 months} of visits similar to those in SMOV proposal 11436 {activity ID WFC3-23}. The data will be analyzed using the code and techniques described in ISR WFC3 2008-40 {Hartig}. Profiles of encircled energy will be monitored and presented in an ISR. If an update to the SIAF is needed, {V2,V3} locations of stars will be obtained from the Flight Ops Sensors and Calibrations group at GSFC, the {V2,V3} of the reference pixel and the orientation of the detector will be determined by the WFC3 group, and the Telescopes group will update and deliver the SIAF to the PRDB branch. The specific PSF metrics to be examined are encircled energy for aperture diameter 0.15, 0.20, 0.25, and 0.35 arcsec, FWHM, and sharpness. {See ISR WFC3 2008-40 tables 2 and 3 and preceding text.} about 20 stars distributed over the detector will be measured in each exposure for each filter. The mean, rms, and rms of the mean will be determined for each metric. The values determined from each of the 4 exposures per filter within a visit will be compared to each other to see to what extent they are affected by "breathing". Values will be compared from visit to visit, starting with the values obtained during SMOV after the fine alignment has been performed, to see if the measures of the compactness of the PSF indicate degradation over time. The analysis will be repeated for stars on the inner part of the detector and stars on the outer part of the detector to check for differential degradation of the PSF. As an example of the analysis, one can examine the sharpness of the F275W PSF exposures made during thermal vacuum testing {ISR WFC3 2008-40}. To compare two samples, one can define the PSFs on each CCD chip as a sample of 8. The mean, rms, and rms of the mean sharpness are 0.0676, 0.0093, and 0.0035 for one chip, and 0.0701, 0.0085, and 0.0032 for the other. The difference of the means is 0.0025 and the statistical error in that difference is 0.0048, so the difference is not significant.;
No associations
LandOfFree
WFC3 UVIS Image Quality does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with WFC3 UVIS Image Quality, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and WFC3 UVIS Image Quality will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1320852