Computer Science – Performance
Scientific paper
Aug 2007
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2007wfc..rept...17h&link_type=abstract
Instrument Science Report WFC3 2007-17, 8 pages
Computer Science
Performance
Hubble Space Telescope, Hst, Space Telescope Science Institute, Wide Field Camera 3, Wfc3, Tv2 Test, Thermal Vacuum 2 Test
Scientific paper
Images taken during WFC3's Thermal Vacuum 2 (TV2) testing have been used to characterize the performance of the UVIS channel shutter. Images with exposure times ranging from 0.5 to 30 seconds have been used to examine shutter shading, accuracy, and repeatability. Fits to ratio images reveal no shutter shading effects down to the 0.77% level, corresponding to an exposure time difference across the image of no more than 0.004 sec (CEI Spec is 0.01 sec). Measured exposure times are within 2.4% of commanded values in all cases except the 0.5 second images. Similar to results from TV1, these data show the UVIS shutter fails to meet the CEI Spec for shutter repeatability in 5 of the 9 commanded exposure times.
No associations
LandOfFree
WFC3 TV2 Testing: UVIS Shutter Stability and Accuracy does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with WFC3 TV2 Testing: UVIS Shutter Stability and Accuracy, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and WFC3 TV2 Testing: UVIS Shutter Stability and Accuracy will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1800000