Wavelength Accuracy of the Keck HIRES Spectrograph and Measuring Changes in the Fine Structure Constant

Astronomy and Astrophysics – Astrophysics – Cosmology and Extragalactic Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

19 pages, 10 figures, to appear in ApJ, Dec 2009 Many corrections and changes made, some new figures

Scientific paper

10.1088/0004-637X/708/1/158

We report on an attempt to accurately wavelength calibrate four nights of data taken with the Keck HIRES spectrograph on QSO PHL957, for the purpose of determining whether the fine structure constant was different in the past. Using new software and techniques, we measured the redshifts of various Ni II, Fe II, Si II, etc. lines in a damped Ly-alpha system at z=2.309. Roughly half the data was taken through the Keck iodine cell which contains thousands of well calibrated iodine lines. Using these iodine exposures to calibrate the normal Th-Ar Keck data pipeline output we found absolute wavelength offsets of 500 m/s to 1000 m/s with drifts of more than 500 m/s over a single night, and drifts of nearly 2000 m/s over several nights. These offsets correspond to an absolute redshift of uncertainty of about Delta z=10^{-5} (Delta lambda= 0.02 Ang), with daily drifts of around Delta z=5x10^{-6} (Delta lambda =0.01 Ang), and multiday drifts of nearly Delta z=2x10^{-5} (0.04 Ang). The causes of the wavelength offsets are not known, but since claimed shifts in the fine structure constant would result in velocity shifts of less than 100 m/s, this level of systematic uncertainty makes may make it difficult to use Keck HIRES data to constrain the change in the fine structure constant. Using our calibrated data, we applied both our own fitting software and standard fitting software to measure (Delta alpha)/alpha, but discovered that we could obtain results ranging from significant detection of either sign, to strong null limits, depending upon which sets of lines and which fitting method was used. We thus speculate that the discrepant results on (Delta alpha)/alpha reported in the literature may be due to random fluctuations coming from under-estimated systematic errors in wavelength calibration and fitting procedure.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Wavelength Accuracy of the Keck HIRES Spectrograph and Measuring Changes in the Fine Structure Constant does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Wavelength Accuracy of the Keck HIRES Spectrograph and Measuring Changes in the Fine Structure Constant, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Wavelength Accuracy of the Keck HIRES Spectrograph and Measuring Changes in the Fine Structure Constant will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-442516

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.