VLBA Scientific Memorandum n. 31: Astrometric calibration of mm-VLBI using "Source/Frequency Phase Referenced" observations

Astronomy and Astrophysics – Astrophysics – Instrumentation and Methods for Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

16 pages, 4 figures, VLBA Scientific Memo n. 31

Scientific paper

In this document we layout a new method to achieve "bona fide" high precision Very-Long-Baseline-Interferometry (VLBI) astrometric measurements of frequency-dependent positions of celestial sources (even) in the high (mm-wavelength) frequency range, where conventional phase referencing techniques fail. Our method, dubbed "Source/Frequency Phase Referencing" (SFPR) combines fast frequency-switching (or dual-frequency observations) with the source switching of conventional phase referencing techniques. The former is used to calibrate the dominant highly unpredictable rapid atmospheric fluctuations, which arise from variations of the water vapor content in the troposphere, and ultimately limit the application of conventional phase referencing techniques; the latter compensates the slower time scale remaining ionospheric/instrumental, non-negligible, phase variations. For cm-VLBI, the SFPR method is equivalent to conventional phase referencing applied to the measurement of frequency-dependent source positions changes ("core-shifts"). For mm-VLBI, the SFPR method stands as the only approach which will provide astrometry. In this memo we layout the scope and basis of our new method, along with a description of the strategy and a successful demonstration of the application of this new astrometric analysis technique to the highest frequency VLBA observations, at 86 GHz. Our previous comparative astrometric analysis of cm-VLBI observations, presented elsewhere, produced equivalent results using both methods.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

VLBA Scientific Memorandum n. 31: Astrometric calibration of mm-VLBI using "Source/Frequency Phase Referenced" observations does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with VLBA Scientific Memorandum n. 31: Astrometric calibration of mm-VLBI using "Source/Frequency Phase Referenced" observations, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and VLBA Scientific Memorandum n. 31: Astrometric calibration of mm-VLBI using "Source/Frequency Phase Referenced" observations will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-35652

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.