Thermal background fluctuations at 10 micron measured with VLTI/MIDI

Other

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

2

Scientific paper

We present an experiment to measure the thermal background level and its fluctuations with the European Southern Observatory (ESO) Very Large Telescope Interferometer (VLTI). The Mid Infrared Instrument (MIDI) operating between 8 and 12 micron was used in both dispersed and non-dispersed modes. By using an interferometric instrument, in non-interferometric mode, we probe the same optical path as can be expected for other infrared interferometric instruments, e.g. GENIE and MIDI itself. Most of the infrared thermal background detected with MIDI originates from the VLTI infrastructure. This can be attributed to the absence of a pupil re-imaging mirror. Only for a small region around the optical axis of the system the signal from the VLTI infrastructure can be considered small and the atmospheric background fluctuations can be characterized. The fluctuations of the thermal emission are described in terms of their power spectral densities (PSD). We have identified two regions in the PSD. For the low frequency range (0-10 Hz) the fluctuations are dominated by the Earth atmosphere. The slope of the log-log PSD is close to -1. For the high frequency (larger than 10 Hz) range the fluctuations are due to photon noise and the PSD flattens off. Many narrow peaks are present in the PSD. Peaks at 1 and 50 Hz occur in almost all data sets and are identified as the effects of the MIDI closed cycle cooler and the power lines respectively. Other peaks at 10 and 30 Hz, as well as peaks above 50 Hz, are assumed to be VLTI or MIDI-specific frequencies.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Thermal background fluctuations at 10 micron measured with VLTI/MIDI does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Thermal background fluctuations at 10 micron measured with VLTI/MIDI, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Thermal background fluctuations at 10 micron measured with VLTI/MIDI will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1810500

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.