The study of passive flow control device performance at low inlet subcooling

Statistics – Applications

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

Passive flow control devices (PFCDs) are normally used for flow measurement and flow regulation in many liquid flow systems. The typical PFCDs are venturis, orifices, nozzles, and capillary tubes. The PFCDs have several advantages over active flow control valves in thermal-fluid systems. They require no electrical power, data, command signal for operation and are not subject to wear or breakage, as well as the need of feedback control. When liquid flow venturi cavitates, it has the ability to passively control the flow in thermal-fluid systems at the choked flow regime. However, when the cavitating venturi (CV) operates at low value of inlet subcooling to conserve electrical power, an all-liquid overflow phenomenon can occur. If cavitation cannot be guaranteed in CV, then the constant flow rate performance of CV could not be obtained. Then, the CV may not be the best choice for the thermal-fluid control systems. For this reason, the main objective of this study is to evaluate the performance of possible PFCDs at low inlet subcooling. Experiments were performed for the alternate PFCDs of orifice, nozzle, and capillary tube at low levels of inlet subcooling in order to explore the physical phenomena of the PFCD relevant to their operation parameters. The test results of PFCDs are compared with CV's performance, and recommendations are made for the best type of passive flow control device at low inlet subcooling for the industrial and aerospace thermal-fluid control system applications.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

The study of passive flow control device performance at low inlet subcooling does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with The study of passive flow control device performance at low inlet subcooling, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and The study of passive flow control device performance at low inlet subcooling will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1188807

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.