The first measured Mn II and Mn III Stark broadening parameters

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

12

32.70.-N

Scientific paper

The shapes and shifts of the astrophysically interesting 11 singly and 3 doubly ionized manganese (Mn II and Mn III, respectively) spectral lines have been obtained in the laboratory helium plasma at a 49,000 K electron temperature and 1.3 × 1023 m-3 electron density. At mentioned plasma conditions, the Stark broadening has been found as the dominant mechanism in the line shape and shift formation. Our measured Stark widths (W) and shifts (d) are the first experimental data in Mn II and Mn III spectra and many of them represent the first published Mn II and Mn III Stark broadening parameters. Manganese atoms, as impurities in the driving gas, have been introduced by erosion from the manganese bands fixed on the discharge electrodes providing conditions free of self-absorption. Our W and d values are compared with the single calculated data set in the case of two Mn II multiplets, only. An agreement was found in the case of the Stark shift sign. Our measured W values are much higher than the calculated ones. At the above mentioned helium plasma conditions, the line splitting in a hyperfine structure has been overpowered by Stark and Doppler broadenings in the case of the Mn II lines belonging to the 3d4saS2 3d4pzP1,2,3o transition (293.3055, 293.9308 and 294.9205 nm). We estimate that at electron densities below 1021 m-3 and electron temperatures below 8000 K the components in the hyperfine structure can play an important role in the mentioned Mn II line shape formation.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

The first measured Mn II and Mn III Stark broadening parameters does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with The first measured Mn II and Mn III Stark broadening parameters, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and The first measured Mn II and Mn III Stark broadening parameters will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-796261

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.