The Effect of Rotation on Calibrators for Ground-based Interferometry

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

1

Catalogs, Stars: Early-Type, Stars: Rotation, Techniques: Interferometric

Scientific paper

We consider the problem introduced by rotation in the use of early-type stars as calibrators for optical interferometry. These objects have high surface brightnesses and hence are relatively bright, even with small angular diameters. However, rotation can introduce changes in the predicted visibilities well in excess of the uncertainties in the various diameter-magnitude-color calibrations. Measurements of the projected rotational velocity constrain these effects, but the constraints are complicated and not easily evaluated when selecting potential calibrators. Furthermore, the magnitude of the variations depends on the details of the interferometer, such as latitude, baseline length, and operating wavelength. Nevertheless, using measured magnitudes, colors, parallaxes, and projected rotational velocities, and estimating masses from standard evolutionary grids, we are able to calculate histograms that approximate the probability distribution of the visibilities and allow us to characterize the width of the distribution of squared visibilities and the total range induced by rotation. We have found that proximity to the ZAMS adds a valuable constraint, allowing stars with moderate rotation to be reliable calibrators in a number of cases. Catalogs characterizing the sensitivity of the visibilities of potential calibrators to rotation are presented for a number of standard interferometer configurations.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

The Effect of Rotation on Calibrators for Ground-based Interferometry does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with The Effect of Rotation on Calibrators for Ground-based Interferometry, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and The Effect of Rotation on Calibrators for Ground-based Interferometry will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1360252

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.