Josephson point-contact detectors can be used to make radio-astronomical measurements of centimeter and millimeter waves. This paper presents an experimental study of the effect of background noise on the characteristics of such a detector. A reduction of the noise temperature from about 300 K to about 10 K significantly improves the sensitivity of the detector. The experimental results agree well with theoretical calculations.
Etkin V. S.
Il'in V. A.
Shurminova T. M.
No associations
LandOfFree
The effect of background radiation on the characteristics of a Josephson detector does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with The effect of background radiation on the characteristics of a Josephson detector, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and The effect of background radiation on the characteristics of a Josephson detector will most certainly appreciate the feedback.