A Cylindrical Inverted Converter (CIC), made by Lutch, with the emitter on the outside was tested in a vacuum furnace supplying radiant heat to the emitter outer surface. The collector, coaxial with the emitter, has an integral heat pipe with sodium as the working fluid, which carries the heat dissipated in the collector to a radiating area with a coating of alumina and sub-stoichiometric TiO2. The CIC is a proof-of-principle device which will lead to the development of multi-cell inverted converter assemblies for space solar power systems. The thermionic performance at emitter temperatures of 1800 and 1900 K is presented. .
No associations
LandOfFree
Testing of a single cell cylindrical inverted converter does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Testing of a single cell cylindrical inverted converter, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Testing of a single cell cylindrical inverted converter will most certainly appreciate the feedback.