Statistics – Applications
Scientific paper
Dec 1993
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1993spie.2009..121b&link_type=abstract
Proc. SPIE Vol. 2009, p. 121-127, X-Ray Detector Physics and Applications II, Victor J. Orphan; Ed.
Statistics
Applications
1
Scientific paper
Preliminary investigations were carried out to evaluate the resolution of Cd(subscript 1-x)Zn(subscript x)Te detectors at temperatures achievable with commercially available, low power Peltier refrigerators. Detectors were in the form of cubes, 2 mm on a side. They were tested using a preamplifier with optical feedback. The input FET was cooled along with the detectors. Resolutions of 409 eV and 326 eV were observed at the 5.9 keV line of Fe-55, at temperatures of -10 degree(s)C and -20 degree(s)C, respectively. Results indicate that a straightforward extension of this work will lead to resolutions well below 200 eV.
Apotovsky Boris A.
Butler Jack F.
Niemela A.
Sipila Heikki
No associations
LandOfFree
Sub-keV resolution detection with Cd1-xZnxTe detectors does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Sub-keV resolution detection with Cd1-xZnxTe detectors, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Sub-keV resolution detection with Cd1-xZnxTe detectors will most certainly appreciate the feedback.