Statistics – Applications
Scientific paper
Nov 1993
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1993spie.1952..329c&link_type=abstract
Proc. SPIE Vol. 1952, p. 329-337, Surveillance Technologies and Imaging Components, Sankaran Gowrinathan; C. Bruce Johnson; Jame
Statistics
Applications
Scientific paper
The continuing effort to improve detectors for low light applications has resulted in the development of imaging photon counting detectors. One such device is the MAMA (Multi- Anode Microchannel Array) detector fabricated by Ball Aerospace. This paper provides a brief overview of the STIS (Space Telescope Imaging Spectrograph) MAMA detector and a detailed description of the analog signal processing electronics. The analog signal processing circuit is built using two unique Ball Aerospace and Communications Group (BACG) designed ASICs (application specific integrated circuits). Each MAMA detector analog signal processing channel uses a pair of the ASICs. The first is a charge to voltage amplifier and the second a voltage discriminator. The amplifier has lower noise and higher speed than previous BACG designs. Its first stage gain bandwidth is 10 GHz with an equivalent input noise voltage of about 1 nV per root hertz. It has a single ended input and differential output to drive the voltage discriminator. The voltage discriminator ASIC has differential input and single ended, CMOS compatible, output. The system has a 120 ns pulse pair resolution with 21 ns amplitude dependent timing uncertainty. Calculated false event rate, for prototype devices, is 1 count in 107 sec with 100 pF detector capacitance and a 20,000 electron threshold. Counting rates greater than 1 million per second per channel can be accommodated. Both ASICs have much lower power consumption than previous discrete designs. The ASIC process used allows the fabrication of extremely robust devices while reducing the total number of parts.
Cole Edward H.
Smeins Larry G.
Stechman John M.
No associations
LandOfFree
STIS ASIC charge-amp and voltage discriminator for MAMA detector readout does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with STIS ASIC charge-amp and voltage discriminator for MAMA detector readout, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and STIS ASIC charge-amp and voltage discriminator for MAMA detector readout will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-815379